Failure phenomenon:Turn on the power, turn the electric key, start the diesel engine. Feel the diesel engine has started, but after releasing the start button, the diesel engine stopped again. Observe carefully, in the release of the start button instantly, the parking solenoid valve at the same time de-energized (demagnetization), back to the parking position.
Cause analysis: the diesel engine can fire, which indicates that the diesel engine fuel system is not a problem, so turn your attention to the electrical system, DEUTZ diesel engine parking solenoid valve works is energized through the oil, power outages due to the loose thread, in the moment of releasing the starter button caused by the parking solenoid valve at the same time power loss. Solution:Tidy up the loose wire connector and tighten it to make good contact.